Extron electronic DTP T UWP 232/332 D manual Remote Control, Contact Closure Control

Models: DTP T HWP 232/332 D DTP T UWP 232/332 D

1 31
Download 31 pages 63.09 Kb
Page 22
Image 22

Remote Control

This section includes:

Contact Closure Control

Simple Instruction Set Control

The DTP T HWP D and DTP T UWP D family of transmitters can be remotely controlled via their front panel configuration (USB) port, rear panel Remote RS-232 port, and rear panel Remote Contact port. Remote control devices can be:

A host device such as a computer or control system and the Extron Simple Instruction Set (SIS)

A contact closure device such as an Extron KP 6 Keypad Control or a Show Me video cable

Contact Closure Control

The rear panel Remote port provides a way to select an input to the extender using a remote contact closure device. The contact closure pin assignments are detailed in “Contact” of item C on pages 9 and 11.

To select a different input number using a contact closure device, momentarily short the pin for the desired input number to ground. To force one of the inputs to be always selected, leave the short to ground in place.

DTP T HWP/UWP 232/332 D Transmitters • Remote Control 16

Page 22
Image 22
Extron electronic DTP T UWP 232/332 D, DTP T HWP 232/332 D Remote Control, Contact Closure Control, This section includes