DTP T HWP/UWP 232/332 D Transmitters • Installation and Operation 4
Installation and
Operation
This section describes the installation and the operation of the extenders, including:
Mounting the Transmitter
DTP T HWP 232 and 332 D Connections
DTP T UWP 232 and 332 D Connections
TP Cable Termination and Recommendations
Power Supply Wiring
RS-232 and IR Connector Wiring
Operation
Mounting the Transmitter
ATTENTION:
Installation and service must be performed by authorized personnel.
The installation must conform to national and local building, electrical, and safety
codes and to the size requirements of the wall plate.
The transmitters can be installed in a two-gang electrical wall box, or with a mud ring, with a
Decora wall plate cover (supplied).
UL and Safety Guidelines
The following UL guidelines pertain to the installation of the Decora transmitters into a wall
or furniture.
These units are not to be connected to a centralized DC power source or used beyond
their rated voltage range.
These units must be installed in UL Listed wall boxes.
These units must be installed with conduit in accordance with National Electrical Code.