Command Function

SIS Command

Response

Additional Description

 

(Host to Unit)

(Unit to Host)

 

Picture adjustment (RGB input only, UWP models only )

Set pixel phase value

E2*X3)PHAS}

Phas2*X3)]

 

Increment pixel phase value

E2+PHAS}

Phas2*X3)]

X3) = Pixel phase (0-63, default is 32)

Decrement pixel phase value

E2-PHAS}

Phas2*X3)]

 

View pixel phase value

E2PHAS}

X3)]

 

 

 

 

 

Set total pixels value

E2*X3!TPIX}

Tpix2*X3!]

 

Increment total pixels value

E2+TPIX}

Tpix2*X3!]

X3! = ±255 of default value (depends

 

 

 

on input rate)

Decrement total pixels value

E2-TPIX}

Tpix2*X3!]

 

View total pixels value

E2TPIX}

X3!]

 

 

 

 

 

Set horizontal start value

E2*X3@HSRT}

Hsrt2*X3@]

 

Increment horizontal start value

E2+HSRT}

Hsrt2*X3@]

X3@ = 0-255 (default is 128)

Decrement horizontal start value

E2-HSRT}

Hsrt2*X3@]

 

View horizontal start value

E2HSRT}

X3@]

 

 

 

 

 

Set vertical start value

E2*X3@VSRT}

Vsrt2*X3@]

 

Increment vertical start value

E2+VSRT}

Vsrt2*X3@]

X3@ = 0-255 (default is 128)

Decrement vertical start value

E2-VSRT}

Vsrt2*X3@]

 

View vertical start value

E2VSRT}

X3@]

 

DTP T HWP/UWP 232/332 D Transmitters • Remote Control 21

Page 27
Image 27
Extron electronic DTP T HWP 232/332 D, DTP T UWP 232/332 D manual Command Function SIS Command Response, X3@