DXP DVI Pro and DXP HDMI Series • Remote Control 31

Command Function

ASCII Command

Response

Additional Description

(Host to Switcher)

(Switcher to Host)

 

 

 

 

 

 

 

 

 

 

IP Setup (Continued)

 

 

 

Set gateway IP address

EX3^CG}

IpgX3^]

 

Read gateway IP address

ECG}

X3^]

 

Set DHCP on and off

EX4^DH}

IdhX4^]

 

Read DHCP on/off status

EDH}

X4^]

 

Configure current port timeout

E0*X5*TC}

Pti0*X5*]

 

Read current port timeout

E0TC}

X5*]

 

Configure global IP port timeout

E1*X5*TC}

Pti1*X5*]

 

Read global IP port timeout

E1TC}

X5*]

 

Set verbose mode

EX5#CV}

VrbX5#]

 

Read verbose mode

ECV}

X5#]

 

NOTE: X3^ = IP or Gateway address or subnet mask nnn.nnn.nnn.nnn

X4^ = DHCP status

0

= DHCP off, 1 = DHCP on

X5# = Verbose mode

0

= clear or none (default for Telnet connection)

 

1

= verbose mode (default for RS-232/RS-422 connection)

 

2

= tagged responses for queries

 

3

= verbose mode and tagged for queries

X5* = Port timeout interval 1

(10 seconds) 65000 (default is 30 = 300 seconds = 5 minutes)