Installation and Operation, cont’d

EDID 101D/EDID 101V Operation

The EDID 101 can either record EDID from a display device or a preprogrammed EDID can be selected using the rotary and DIP switches.

Recording a display EDID

To record a new EDID into memory:

1.Turn the rotary switch (D) to position 0.

NThe DIP switch positions have no effect in this mode.

2.Apply power to the EDID 101 by connecting a power source.

NIf power is not available from a video source, an external 12 VDC power supply can be used. The green LED will be lit when power is available.

3.Connect the display device to the output of the

EDID 101 using a DVI (EDID 101D) or a VGA (EDID 101V) cable.

NTo capture analog EDID on the EDID 101D, a DVI-A to VGA adapter must be used.

4.Power on the display device.

NAlthough the EDID 101 supplies 5 VDC to power the EDID circuitry of a display device, power on the display device to ensure that data is being transmitted during the recording process.

5.Press and hold the recessed record button (B) until the LED flashes red rapidly, then release the button. The LED continues to flash red, then returns to solid green when the EDID data has been stored. The display can now be disconnected.

NIf an external supply was used for recording, it can now be disconnected.

6.Install the EDID 101 into the system.

10EDID 101D/EDID 101V • Installation and Operation

Page 14
Image 14
Extron electronic EDID 101V, EDID 101D Recording a display Edid, Apply power to the Edid 101 by connecting a power source