Extron electronic FPC 5000 manual 12 - DSVP screen

Models: FPC 5000

1 60
Download 60 pages 43.32 Kb
Page 41
Image 41
DSVP screen

DSVP screen

You can monitor each RGBHV and RGBS input to see if active sync signal(s) are present on the DSVP™ (Digital Sync Validation Processing™) screen (figure 3-12). Access the DSVP screen by touching the blue User > amber DSVP buttons.

Figure 3-12 — DSVP screen

Where an input has active sync present, the DSVP screen reports a snapshot in time of the frequencies in the horizontal and vertical frequency fields. Where no active sync signals are present, the DSVP screen shows —— in the horizontal and vertical frequency fields. Inputs that have not been virtualized (refer to the Matrix 12800 Wideband, Sync, or Audio Switchers User’s Manual, part #68-556-01) or for which there is not a sync BME are marked by “n/a” in the horizontal and vertical frequency

fields Figure 3-12 — DSVP screen. Update the DSVP screen to display fresh frequency readings by touching the green Update button. Manual background

FPC 5000 Front Panel Controller • Matrix 12800 Operation 3-21

Page 41
Image 41
Extron electronic manual 12 - DSVP screen, FPC 5000 Front Panel Controller Matrix 12800 Operation