Introduction
About this Manual
This manual contains information about the Extron MCP 1000 master and slave remote control panels — the MCP 1000M and the MCP 1000S — and provides information on how to operate and configure them.
In this manual, "MCP 1000" is used to refer to either unit. The terms "master," "slave," "MCP 1000M," and "MCP 1000S" are used to refer specifically to one unit or the other.
About the MCP 1000
The MCP 1000 is a multipurpose control panel that can be part of an A/V presentations system, or dedicated to controlling a particular Extron device.
There are two versions of the MCP 1000:
•MCP 1000M (Master), which includes an
•MCP 1000S (Slave), which has neither an
A master can also function as a slave, if necessary.
The MCP 1000M can control any Extron SW switcher, system switcher, or matrix switcher that uses Extron’s Simple Instruction Set (SIS™) commands.
The MCP 1000 features
An MCP 1000M can receive
A slave MCP 1000 uses a
The MCP operating modes include:
•Remote switching control for an Extron switcher or a matrix switcher (with MCP 1000 master only)
•Input selection for a switcher
•Global presets (with matrix switchers)
•Room presets (with Matrix 3200/6400 only).
Although slave units must be given a unique address
(1 – 64) within a system, redundant units can be set up to allow identical control from more than one location.
Features
•Front panel includes 16 large, illuminated push buttons.
•Graphic/text inserts are provided for button assignments.
•Internal power supply, 100 VAC – 240 VAC, 50/60 Hz
•Works with multiple MCP 1000 and MKP 1000 units.
•Controls any
•Includes brackets for rack, table, or shelf mounting.
•Enclosure is 1U high and 5.0" deep.
•LCD panel displays the function name and number.
Button functions
The first four buttons on the left are used during setup. During normal operation, however, they function the same as the other 12 buttons — as program or selection buttons. The MCP 1000 can be a control panel for many Extron products.
Simple Instruction Set (SIS)
The master MCP 1000M is preprogrammed with SIS commands in several categories. After the unit has been configured for an application, appropriate SIS commands are issued when
a button is pressed. Such commands include selecting an input number, a preset number, or a room preset number. For example, if the unit is set up to work with a matrix switcher as output 5 to handle inputs 1 through 16, pressing MCP 1000 panel button 9 selects (ties) input 9 to output 5. See chapter 3, "Operation," for detailed examples with illustrations.
Any MCP 1000S slave unit connected to a master communicates through the
Mounting options
The MCP 1000 comes with a set of brackets for mounting the unit on a rack, or under or through a shelf, table, or podium. MCP 1000 panels can be located in various places throughout a business or educational complex.