Extron electronic MCP 1000 Two, Installation, Introduction, cont’d, Comm-link requirements

Models: MCP 1000

1 21
Download 21 pages 14.14 Kb
Page 7
Image 7
Introduction, cont’d

Introduction, cont’d

MCP 1000 as part of a Matrix 3200/6400 system

When used with an Extron Matrix 3200/6400 switcher, the MCP 1000 has the same functions as the MKP 1000 Remote Keypad. For this type of installation, the MCP 1000 panels are hard-wired to a Matrix 3200/6400 switcher, and they can be mixed with MKP 1000 keypads. For additional information, see the MKP 1000 User’s Manual. As with the MKP 1000, the status of MCP 1000 units can be displayed on the front panel (FPC 1000) of the Matrix 3200/6400.

Demo

Room

Computer

Training Room

MCP 1000 as part of a Matrix 3200/6400 systemChapter2Two MCP 1000 Remote Control Panel

Chapter2Two

Conference

Room

Extron

MKP 1000

Remote Keypad

Videoconference

 

Room

Extron

MCP 1000

Remote Control Panel

Using the MCP 1000 with an MKP 1000 and a Matrix 3200/6400 switcher.

Extron Matrix 6400

Matrix Switcher

Installation

Comm-link requirements

The maximum total cable length in a comm-link system is 1000 feet (305 meters). It doesn’t matter whether the configuration is a daisy-chain, a star, or a combination of both.

The maximum number of MKP 1000 and MCP 1000 units in one system is 64.

Through the comm-link port, an MCP 1000M (master) unit supplies voltage to MKP 1000 units. Matrix 3200/6400 BMEs (Basic Module Enclosures) also supply voltage through the comm-link ports for MKP 1000s.

CAUTION

Damage may occur if more than one voltage source

 

is connected to a system. See page "Comm-link

 

connectors (master or slave)" in chapter 2,

 

"Installation," for more details.
Mounting the MCP 1000

Rear Panel Connections

Changing the Front Panel Button Labels
Using the Button Label Generator
1-4 MCP 1000 • Introduction
Page 7
Image 7
Extron electronic user manual Two, Installation, Introduction, cont’d, MCP 1000 as part of a Matrix 3200/6400 system