Quick Start Guide — MDA EQ Series, cont’d
SmoothRidges
A | A |
SECTION
0.2” (5 mm) MAX
Power Supply
Output Cord
Captive Screw
Connector
Wiring the power cordStep 4
Connect power cords to the input and the outputs, and turn on the equipment.
Step 5
Adjust the potentiometers for the outputs, using an Extron Tweeker.
If using very short output cables, set all pots to the default setting (the arrow on the pot pointing to the dot beside it; see illustration below).
1 | 2 | 3 | 4 |
GAIN EQ GAIN EQ GAIN EQ GAIN EQ
Potentiometers at default settingsIf using long cables, follow these steps:
a. | Supply the Color Bars test signal to the input. |
| (Recommendation: Use an Extron VTG 300 Video Test |
| Generator to generate the test signal.) |
b. | Adjust the Gain pot for output 1 until the signal level at |
| the far end is the same as the input (or the display shows |
| the correct brightness and contrast). |
c. | Adjust the EQ pot for output 1 so that no overshoot or |
| round front corner appears at the far end on the scope (or |
| you see a sharp picture with no smearing). |
d. | Repeat steps 2 and 3 for the rest of the outputs. |
Table of Contents
Chapter 1 • Introduction | |
About this Manual | |
About the MDA EQ Series Mini Distribution |
|
Amplifiers | |
Models | |
Features | |
Connection diagrams | |
Chapter 2 • Installation and Operation | |
Mounting the MDA EQ Series | |
Tabletop use | |
Rack mounting | |
Furniture mounting | |
Projector mounting | |
Rear Panel Features and Cabling | |
Front Panel Features and Operation | |
Appendix A • Specifications, Part Numbers, and |
|
Accessories | |
Specifications | |
Models | |
Included Parts | |
Optional Accessories |
All trademarks mentioned in this manual are the properties of their respective owners.
Printed in USA
09 04
VersaTools® MDA EQ Series • Table of Contents | i |