Installation
Installation Overview
To install and set up an Extron MMX 42/62 switcher for operation, follow these steps:
1Turn off all of the equipment. Ensure that the video sources and the output display are all turned off and disconnected from the power source.
2Mount the switcher. See "Mounting the Switcher", below.
3 | Attach the cables. See "Rear Panel Cabling" in this chapter. |
4 | Plug in the power supply, then turn on the display devices |
| and the input devices. |
5Set the audio gain and attenuation. See the "Set input audio level" SIS commands in chapter 4, "Remote Control".
Mounting the Switcher
CInstallation and service must be performed by authorized personnel only.
The
Tabletop placement
Affix the four included rubber feet to the bottom of the unit and place it in any convenient location.
Rack mounting
For optional rack mounting, mount the switcher on any of the following rack shelves:
•RSF 123
•RSB 123
•RSU 126
•RSB 126
•RSU 129
•RSB 129
RSF 123 3" Rack Shelf Kit
1/2 Rack Width Front
False Faceplate
Use 2 mounting holes on | (2) |
opposite corners. | |
| Screws |
Figure 2-1 — Mounting the switcher on a 3-inch rack shelf
UL guidelinesThe following Underwriters Laboratories (UL) guidelines pertain to the installation of the matrix switcher into a rack.
1. | Elevated operating ambient temperature — If the |
| equipment installed in a closed or |
| assembly, the operating ambient temperature of the |
| rack environment may be greater than room ambient |
| temperature. Therefore, install the matrix switcher in |
| an environment compatible with the maximum ambient |
| temperature (TMA = 122 °F , +50 °C) specified by Extron. |
2. | Reduced air flow — Install the equipment in a rack so that |
| the amount of air flow required for safe operation of the |
| equipment is not compromised. |
3. | Mechanical loading — Mount the equipment in the rack |
| so that a hazardous condition is not achieved due to |
| uneven mechanical loading. |
4. | Circuit overloading — Connect the equipment to |
| the supply circuit and consider the effect that circuit |
| overloading might have on overcurrent protection and |
| supply wiring. Appropriate consideration of equipment |
| nameplate ratings should be used when addressing this |
| concern. |
MMX 42/62 Series Matrix Switchers • Installation | MMX 42/62 Series Matrix Switchers • Installation |