Installation and Operation, cont’d

See chapter 3, “Serial Communication” for Simple Instruction Set (SIS) commands to communicate with the MSW 4V SDI rs via RS-232.

D

Contact connector — Connect a remote contact

CONTACT

 

closure device to the MSW for remote control

 

 

 

 

 

of the switcher, or daisy chain it to other MSWs

 

2

3

 

 

for remote control of all the units, via this 5-pin

1

4

 

 

 

 

 

 

captive screw connector.

 

 

 

 

NThe switcher must be in normal (manual) mode for contact closure to work. See "Mode selection", later in this chapter.

To select an input using a contact closure device, such as an Extron CCR 204 contact closure remote control (part #60-794-02) or a locally constructed device, momentarily short the pin for the desired input number to logic ground (pin 5). To force one of the inputs to be always selected, leave the short in place. The short overrides any front panel input selections.

You can also daisy chain multiple MSWs via the Contact connector for front panel control of all switchers; touch the input button on one MSW to switch all MSWs. Wire pin 1 to pin 1, pin 2 to pin 2, and so on.

E

Power connector — Plug the external 12 VDC power supply

 

into this 2-pin, 3.5 mm captive screw connector. The power

 

supply is included with the unit.

In the event that power is disconnected from the MSW, the unit retains mode and input settings.

NThe power connector on the rear panel is orange; however, the plug for the power cord may be either orange or blue. Either color plug can be connected to the rear panel receptacle.

To wire the connector, do the following:

1.Cut the DC output cord to the length needed.

2.Strip the jacket to expose 0.2” (5 mm) of the conductors for the blue captive screw plug, or 0.3” (7 mm) for the orange plug.

Smooth

Ridges

 

A

A

SECTION A–A

Power Supply

Tie Wrap

Output Cord

 

0.3” (7 mm) MAX

Orange Captive Screw

Connector

Figure 2-6 — Power wiring

WExposing more than the amount of wire described above could allow the stripped wires to touch each other, causing a short circuit. This could result in the external DC power supply overheating and/or burning.

NStripping the wires to expose less than the recommended amount causes them to slide out of the connector too easily, even if they are tightly pinched by the captive screws.

3.Slide the leads into the supplied captive screw plug and lock them, using an Extron Tweeker (small screwdriver).

4.Use the supplied tie-wrap to strap the power cord to the extended tail of the connector.

5.To verify the power cord’s polarity before connecting it, plug in the power supply with no load and check the output with a voltmeter.

CDo not tin the stripped power supply leads before installing the captive screw connector. Tinned wires are not as secure in the captive screw connectors and can be easily pulled out. They may also break after being bent several times.

WThe two power cord wires must be kept separate while the power supply is plugged in. Remove power before wiring.

Alternately, an Extron PS 123 12 VDC, 3 amp power supply, (part #60-814-01), can power up to eight MSWs or other Extron 12 VDC devices using only one AC power connector.

2-6

MSW 4V SDI rs • Installation and Operation

MSW 4V SDI rs • Installation and Operation

2-7

Page 11
Image 11
Extron electronic MSW 4V SDI rs user manual Power wiring

MSW 4V SDI rs specifications

The Extron MSW 4V SDI RS is a high-performance, four-input, SDI switcher that meets the needs of professionals in broadcasting, corporate, educational, and live event environments. The device is designed to facilitate seamless switching between multiple SDI video sources while ensuring high-quality video output. With its robust build and advanced features, the MSW 4V SDI RS is an excellent choice for applications requiring reliable signal management.

One of the key features of the MSW 4V SDI RS is its ability to support a wide range of video formats, including high-definition 720p and 1080p signals, making it versatile for diverse video production requirements. The switcher can handle standard definition (SD), high definition (HD), and even 3G-SDI in one compact unit. This adaptability ensures smooth integration into existing setups without the need for additional converters or signal processors.

In terms of connectivity, the MSW 4V SDI RS is equipped with four SDI input ports, allowing users to connect multiple sources to a single device. The switcher also boasts dual SDI outputs, providing flexibility in routing and distribution of the selected video signal to different displays or recording devices. This feature is particularly valuable in live event scenarios, where real-time switching and signal distribution are critical.

The MSW 4V SDI RS employs advanced digital processing technology to maintain signal integrity and minimize latency during switching operations. Its design includes features such as automatic input detection and signal reclocking, ensuring optimal performance across various video formats. This attention to detail in signal management guarantees that users experience minimal disruption, even during critical moments of a live broadcast.

Furthermore, the MSW 4V SDI RS offers user-friendly controls and monitoring options. Its intuitive front-panel interface allows operators to easily navigate between inputs and outputs, while LED indicators provide immediate feedback on signal status. For more advanced setups, the switcher supports RS-232 control, enabling integration with third-party control systems or automation setups, enhancing flexibility and usability in professional environments.

In summary, the Extron MSW 4V SDI RS is a feature-rich, reliable SDI switcher that excels in managing multiple video sources for various applications. With its advanced technology, robust build quality, and user-centric design, it is an essential tool for professionals in need of efficient, high-quality signal routing and switching.