Extron electronic RCP 2000 Applying and Changing a Switching Effect, Detail adjustments, Cuts

Models: RCP 2000

1 23
Download 23 pages 17.17 Kb
Page 12
Image 12
Detail adjustments

Operation, cont’d

Detail adjustments

To apply a horizontal or vertical filter to improve the sharpness of an image, do the following:

1.

Press and release the Detail button. The button lights.

2.

Various levels of detail adjustment are available,

 

depending on the input signal format.

 

To change the vertical filter (if available), rotate the V

 

 

adjustment knob. Choose the filter that provides the

 

 

most improvement to the image detail.

 

 

The availability of some filters depends on the type of

 

 

 

 

switcher that is connected. Check your switcher’s user

 

 

manual for to find out if this feature is supported.

 

To change the horizontal filter (if available), rotate

 

 

the H adjustment knob. Choose the filter that

 

 

provides the sharpest image.

Applying and Changing a Switching Effect

You can switch the program and preview inputs using a variety of switching effects. For a description of each effect, and the technique to implement it, see the instructions for the effect in this section. Unless otherwise indicated, the effects are available for both the ISS and SGS switchers.

Cuts

A cut seamlessly replaces the program image with the preview image. No effect is applied to the switch. As soon as the Cut button is pressed, the switch occurs.

To switch using a cut, do the following:

1.

Press the preview input button that corresponds to the

 

input that you want to switch to.

2.

Press the Cut button. The seamless switch takes effect

 

immediately, and the preview image becomes the new

 

program image.

Dissolves

A dissolve causes the program image to fade out while the preview image fades in (figure 3-2). See Implementing an effect, later in this chapter, for information on how to implement a dissolve.

Dissolve

Figure 3-2 — A dissolve effect

Changing the duration of a dissolve

To change the duration of a dissolve, do the following:

1.

Press the Dissolve button. The Dissolve button lights.

2.

Rotate the Adjust knob next to the buttons. A duration

 

menu appears on the LCD screen, showing the current

 

duration selected for the dissolve. Select any dissolve

 

duration time from 0.2 to 5.0 seconds.

Wipes (SGS only)

The different types of wipes available on the RCP 2000 are described in this section.

Standard wipe

A standard wipe causes the preview image to appear to unroll over the program image horizontally or vertically. A standard wipe can have either hard (sharp) or soft (fuzzy) edges.

The preview image can have the following transitions (see figure 3-3):

From left to right

From right to left

From top to bottom

From bottom to top

Figure 3-3 — Standard wipe transitions

3-6

RCP 2000 • Operation

RCP 2000 • Operation

3-7

Page 12
Image 12
Extron electronic RCP 2000 Applying and Changing a Switching Effect, Detail adjustments, Cuts, Dissolves, Wipes SGS only