Extron electronic user manual Three, Operation, Installation, cont’d, RCP 2000 Installation

Models: RCP 2000

1 23
Download 23 pages 17.17 Kb
Page 9
Image 9
Installation, cont’d

Installation, cont’d

When connecting the RCP 2000 directly (no intermediate device present, such as a network hub) to the ISS 108/408, you must use a crossover cable. See the table on the next page for RJ-45 crossover cable connections.

RJ-45 Ethernet Crossover Cable

 

RCP 2000 end

Intermediate hub, etc., end

Pin

Wire color

Signal

Pin

Wire color

Signal

1

White-orange

Transmit +

3

White-orange

Receive +

 

 

 

 

 

 

2

Orange

Transmit -

6

Orange

Receive -

 

 

 

 

 

 

3

White-green

Receive +

1

White-green

Transmit +

6

Green

Receive -

2

Green

Transmit -

 

 

 

 

 

 

4

Blue

N/A

4

Blue

N/A

 

 

 

 

 

 

5

White-blue

N/A

5

White-blue

N/A

 

 

 

 

 

 

7

White-brown

N/A

7

White-brown

N/A

 

 

 

 

 

 

8

Brown

N/A

8

Brown

N/A

 

 

 

 

 

 

When connecting the RCP 2000 indirectly (intermediate device present, such as a network hub) to the ISS 108/408, you must use a patch (straight-through) cable. See the table below for RJ-45 patch cable connections.

RJ-45 Ethernet Patch Cable

 

RCP 2000 end

SGS 408, ISS 108/408 end

Pin

Wire color

Signal

Pin

Wire color

Signal

1

White-orange

Transmit +

1

White-orange

Receive +

 

 

 

 

 

 

2

Orange

Transmit -

2

Orange

Receive -

 

 

 

 

 

 

3

White-green

Receive +

3

White-green

Transmit +

 

 

 

 

 

 

4

Blue

N/A

4

Blue

N/A

 

 

 

 

 

 

5

White-blue

N/A

5

White-blue

N/A

 

 

 

 

 

 

6

Green

Receive -

6

Green

Transmit -

 

 

 

 

 

 

7

White-brown

N/A

7

White-brown

N/A

 

 

 

 

 

 

8

Brown

N/A

8

Brown

N/A

 

 

 

 

 

 

Chapter3ThreeOperation RCP 2000 Remote Control Panel

Chapter3Three

Operation

Top Panel Controls

Using the Picture Controls

Applying and Changing a Switching Effect

Resetting the Unit

2-6 RCP 2000 • Installation
Page 9
Image 9
Extron electronic RCP 2000 Three, Operation, Installation, cont’d, Top Panel Controls Using the Picture Controls