Extron electronic SW8/12 VGA manual Control, cont’d, Command/Response Table for SIS commands

Models: SW8/12 VGA SW12 VGA ARS

1 41
Download 41 pages 19.76 Kb
Page 27
Image 27
Control, cont’d

Control, cont’d

Command/Response Table for SIS commands

Command

ASCII (Telnet\⤀

Response

Additional description

 

(host to switcher\⤀

(switcher to host\⤀

 

Input Selection

 

 

 

Select video and

X!!

InX!All]

Select input X!video and audio.

audio

 

 

 

Select video only

X!&

InX!Vid]

Select input X!video only.

Select audio only

X!$

InX!Aud]

Select input X!audio only.

Auto Switch

 

 

 

Normal switch mode

1#

F1]

Set switch mode to normal.

Auto switch mode

2#

F2]

Set switch mode to auto.

Input video sensing

Request all inputs’

0S

Sig•X@X@...X@]

status

 

 

Example: (SW8)

0S

Sig•1•1•1•1•0•1•1•0]

Request specific

X!S

X@]

input’s status

 

 

Each X@response is the signal status from each input X!’s signal status.

The input signal is present on inputs

1,2,3,4,6, and 7. No signal is present

on inputs 5 and 8.

X!’s signal status = X@.

Video mute

NThese commands mute and unmute both video outputs.

Mute video

1B/b

VmtX#]

Video mute on.

Unmute video

0B/b

VmtX#]

Video mute off.

Read mute status

B/b

X#]

Video mute status.

Audio mute

NThese commands mute and unmute both audio outputs.

Mute audio

1Z/z

AmtX#]

Audio mute on.

Unmute audio

0Z/z

AmtX#]

Audio mute off.

Read mute status

Z/z

X#]

Audio mute status.

 

 

Output Volume Control (variable audio output\⤀

 

Set audio volume to

X$V

VolX$]

 

a specific level

 

 

 

Example:

75V

Vol75]

Sets output volume to 75.

Increment volume

+V

VolX$]

 

Decrement volume

-V

VolX$]

 

View volume

V

X$]

 

 

 

 

VSW I AAP Compatibility Mode

 

 

Enable/disable

EX!*X#VSWE}

Vswe•X#X#X#......•X#]

X!is an input (1-8 or 1-12).

single input

 

 

 

Enable/disable all

E0*X#VSWE}

Vswe•X#X#X#......•X#]

X#is the enabled/disabled status

inputs

 

 

from each input (0 = disabled,

 

 

 

1 = enabled).

View current status

EVSWE}

Vswe•X#X#X#......•X#]

 

Front panel lockout

 

 

 

Turn front panel

1X/x

ExeX#]

Front panel lockout on.

lockout on

 

 

 

Turn front panel

0X/x

ExeX#]

Front panel lockout off.

lockout off

 

 

 

View front panel

X/x

X#]

Front panel lockout status.

lockout status

 

 

 

3-4 SW8/12 VGA Ars • Control