Remote Control, cont’d
Contact Closure Remote Control
The Remote connector also provides a way to select an input to the switcher using a remote contact closure device. Contact closure control uses pins on the Remote connector that are not used by the
|
|
| Contact |
| |
| PIN | Closure | Function | ||
| 1 | — | In #1 | Input #1 | |
REMOTE | 2 | TX | — | Transmit data | |
3 | RX | — | Receive data | ||
| |||||
| 4 | — | In #2 | Input #2 | |
| 5 | Gnd | Gnd | Ground | |
| 6 | — | In #3 | Input #3 | |
| 7 | — | In #4 | Input #4 | |
| 8 | — | In #5 | Input #5 | |
| 9 | — | In #6 | Input #6 |
To select a different input number using a contact closure device, momentarily short the pin for the desired input number to logic ground (pin 5). To force one of the inputs to be always selected, leave the short to logic ground in place. The short overrides front panel input selections.
IR 102 Infrared Remote Control
The optional Extron IR 102 kit consists of the following components:
•IR 102 handheld remote control unit
•VersaTools IR 102 remote receiver with 3' cable and
•IR detector with 6' cable and captive screw connector
•External 12 VDC power supply
Install and operate the remote control in accordance with the IR 102 User’s Guide included with the remote.
SW6 VGA Audio Switcher | Power |
| |
|
| Supply |
|
|
| 3' Cable | |
|
|
| Control |
| 6' Cable |
|
|
|
|
| |
IR 102 |
| IR 102 Remote |
|
IR 102 Remote Control | IR Detector |
| |
Control Receiver |
| ||
|
|
|
3-8 SW6 VGA Audio • Remote Control
SW6 VGA Audio Switcher
AAppendix A
Reference Information
Specifications
Part Numbers