Installation and Operation, cont’d

6" Deep Rack Shelf

1/2 Rack Width Front False

 

Faceplate

Front false faceplate uses 2 screws.

(2) 4-40 x 3/16" Screws

Use 2 mounting holes on opposite corners.

Figure 2-3 — Mounting a YCS on a 6-inch rack shelf

Back of the rack mounting

The YCS 100 also can be mounted vertically to the front or rear rack supports, using the optional MBB 100 back of the rack mounting kit (Extron part #70-367-01).

Follow these steps to mount the YCS to the rack supports using the back of the rack mounting kit:

1.

If feet were previously attached to the bottom of the YCS,

 

remove them.

2.

Remove the two screws from one side of the YCS. Retain

 

the screws for possible later reassembly.

3.

Attach one bracket to the side of the unit, using the longer

 

screws included in the mounting kit (see figure 2-4, on the

 

next page).

4.

Repeat steps 2 and 3 on the other side of the YCS.

2-4 YCS 100 • Installation and Operation

Figure 2-4 — Attaching the back of rack mounting brackets to the YCS 100

5. Mount the unit to the rack support, using the two included rack screws (see figure 2-5, below).

UEL

B

NE

EGR

DER

Figure 2-5 — Mounting the YCS 100 to a back rack support

YCS 100 • Installation and Operation

2-5

Page 9
Image 9
Extron electronic YCS 100 user manual Installation and Operation, cont’d, Back of the rack mounting