Control Panel

USE

Control Panel

S1

L

T1

T2

T3

T4

The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button.

 

 

LED

FUNCTIONS

L

0/1 Light

 

Turns lighting on and off.

 

 

 

 

T1

0/1 Motor

Fixed

First speed.

 

 

 

When pressed for about 2 seconds the motor is switched off.

T2

Speed

Fixed

Second speed.

T3

Speed

on

Third speed.

 

 

 

 

T4

Speed

Fixed

Max. speed

 

 

Flashing

Intensive speed.

 

 

 

Suitable for the strongest cooking vapours and odours. The function becomes active when the

 

 

 

button is pushed for about 2 seconds. After 10 minutes of functioning it turns off automatically.

 

 

 

This function can be interrupted by means of pressing any of the buttons.

S1

Led

Fixed

Indicates that the Metal grease filters saturation alarm has been triggered, and the filters need to

 

 

 

be washed. The alarm is triggered after 100 working hours. (Reset; check the Maintenance-

 

 

 

paragraph)

 

 

Flashing

indicates that the activated charcoal odour filter saturation alarm has been triggered, and the

 

 

 

filter has to be replaced; the metal grease filters must also be washed. The activated charcoal

 

 

 

odour filter is triggered after 200 working hours. (Activation and Reset; check the Maintenance-

 

 

 

paragraph)

MAINTENANCE

Grease filters

CLEANING METAL GREASE FILTERS

Alarm signal reset

Switch off the lights and extractor motor.

Press button T3 for at least 3 seconds, until the leds start to flash.

Cleaning the filters

• Open the suction cover using the lever provided.

The filters are washable and must be cleaned when the Led S1 lights up or at least every 2 months of operation, or more frequently for particularly heavy usage.

Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.

Wash the filters, taking care not to bend them. Allow them to dry before

refitting.

• When refitting the filters, make sure that the handle is visible on the outside.