SECTION 5

Handling Instructions

5.1 Electrostatic Discharge

The Fairchild Imaging LNL2048S is a metal oxide semiconductor (MOS) device, and as all such devices, has some limited inherent susceptibility to electrostatic discharge (ESD).

All reasonable and customary design steps have been taken to provide ESD protection circuitry. The CMOS technology provides greater immunity to ESD problems than do CCD devices.

Electrostatic charge placed at the sensor could cause charging of the chip which in some situations might not be readily dissipated and minor impact on performance might be temporarily experienced. Therefore, do not insert your finger or any other object into the lens mount barrel.

5.2 Preventing ESD Damage

Please be certain to ground yourself prior to handing the camera.

Ensure that your working environment is grounded, including conductive floor mats. Do not touch the window of the imager.

5.3 Protecting Against Dust, Oil and Scratches

Be certain to avoid dust buildup on the sensor window, where it could block the optical path.

By not touching the surface of the sensor, you avoid introducing oil and avoid scratching the sensor window. Again, you should not insert anything into the lens mount barrel.

5.4 Cleaning the Sensor Window

Use compressed air to blow off particulate.

If for some reason cleaning of the sensor window is required, use lens wiping cloth with a small amount of eyeglass cleaning fluid. Do not use solvent as it may smear the sensor window.

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 32 of 42

Page 32
Image 32
Fairchild CAM/CMOS-2K.LS Handling Instructions, Electrostatic Discharge, Preventing ESD Damage, Cleaning the Sensor Window