LED

This command allows you to change the color. When selecting the option you need to, enter the appropriate single digit number and hit enter. Your screen will be blank during this command

You can input one of the following:

Value

Function

0

Amber

1

Green

2

Red

3

Off

GDA

This command allows you to show all of the DACs (Digital to Analog Converter). When selecting the option you need, enter the appropriate single digit number and hit enter.

The camera returns…

 

3:Gain F_odd = 0.490V

8:GainF_even = 0.490V

2:GainC_odd = 0.235V

6:GainC_even = 0.235V

4:Offset_odd = 1.199V

7:Offset_even = 1.199

1:CML_odd = 1.425V

5:CML_even = 1.425

SDN

This command allows you to select one of the above DAC numbers, and change its value.

Example: SDN + enter + 486 + enter

enter value between 0 - 1023

GDN

This command allows you to verify what you just did under the SDN command. Example: you would input the following GDN + enter + 1

The camera returns a value between 0 - 1023

SAP

Store in Flash both correction memories, all registers and DAC values.

 

Value

Function

Store all parameters

0

Default factory calibrate

 

1

User

 

2

User

RAP

Load from flash to camera. Recall all parameters.

Value Function

0Default factory calibration

1User

2User

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 17 of 42