LED
This command allows you to change the color. When selecting the option you need to, enter
the appropriate single digit number and hit enter. Your screen will be blank during this
command
You can input one of the following:
Value
Function
0 Amber
1 Green
2 Red
3 Off
GDA
This command allows you to show all of the DACs (Digital to Analog Converter). When
selecting the option you need, enter the appropriate single digit number and hit enter.
The camera returns…
3:Gain F_odd = 0.490V 8:GainF_even = 0.490V
2:GainC_odd = 0.235V 6:GainC_even = 0.235V
4:Offset_odd = 1.199V 7:Offset_even = 1.199
1:CML_odd = 1.425V 5:CML_even = 1.425
SDN
This command allows you to select one of the above DAC numbers, and change its value.
Example: SDN + enter + 486 + enter enter value between 0 - 1023
GDN
This command allows you to verify what you just did under the SDN command.
Example: you would input the following GDN + enter + 1
The camera returns a value between 0 - 1023
SAP
Store in Flash both correction memories, all registers and DAC values.
Value Function
Store all parameters 0 Default factory calibrate
1 User
2 User
RAP
Load from flash to camera. Recall all parameters.
Value Function
0 Default factory calibration
1 User
2 User
Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 17 of 42