Fairchild CAM/CMOS-2K.LS user manual Thermal Considerations, Link

Models: CAM/CMOS-2K.LS

1 42
Download 42 pages 27.72 Kb
Page 8
Image 8

Table 1.2.2

Settings and Controls

Function

Factory

User

Camera

 

Calibrated

Settable

Link

Reset to Default Conditions

 

X

X

Fixed Pattern Noise Correction

X

X

X

PRNU Correction

 

X

X

Integration Time

 

X

X

External Synch / Free Run

 

X

X

Pixel Level Gain

 

X

X

Line Synchronization

 

X

X

Test Patterns

X

X

X

1.3 Thermal Considerations

The CAM/CMOS 2K.LS has been carefully designed to separate the camera electronics from the image sensor. In addition, the Fairchild Imaging CMOS sensor runs cooler than a CCD device.

Fairchild Imaging advises waiting until the camera has stabilized thermally before performing offset and gain corrections. You can determine that the camera has stabilized thermally by repeatedly using the "TSB" command to read sensor temperature. When sensor temperature changes less than 0.1°C per minute, the camera has stabilized.

Try to avoid excess temperatures in the ambient around the camera.

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 8 of 42