![13.3AC CONNECTION](/images/new-backgrounds/18943/1894373x1.webp)
ST VERSION DESCRIPTION | ENG | |
|
|
|
13.3AC CONNECTION
The Falcon 15 uses a power entry module with AC switch just closed to the IEC power cord receptacle. It can operate on 110 or 240 VAC, 50/60 Hz AC mains voltages. If the unit is to be used with a mains voltage different to that for which the unit is supplied, set the voltage
The power supply socket has an integral fuse drawer containing the AC power fuse and a spare, both of the same value.
-for 220/230 V AC the fuse is rated at 500 mA T
-for 110/115 V AC tension the fuse is rated at 1 A T
13.4DIGITAL AUDIO INPUT
Transformer balanced
To avoid malfunctions, only one digital connector may be connected at a time. Please keep the
The digital input accepts any sampling rate between 32 and 96 kHz. No user adjustment is necessary since a sample rate converter is built into the unit. Furthermore, digital input automatically recognizes the digital format (AES, EBU, SPDIF, etc.) and the type of connection (optic or coaxial).
Even though both analog and digital input audio cables can be connected, only one input can be set active (analog/digital input selection is done through the software parameter setting - par. 12.1). Input gain and level setting for digital input is fixed.
XLR pinout: | Pin 1 | Gnd |
| Pin 2 | Signal |
| Pin 3 | Return |
Page 37