| Page 23 of 26 |
| |||||
|
|
|
|
|
|
|
|
| Message |
|
|
| Description |
|
|
| MET1:#13 Err. Node=%d cant be | The reported device could not be selected because there |
| ||||
| selected because not defined in | isnt a node descriptor whose Node_ID matches the |
| ||||
| config. |
|
|
| reported device.4 |
|
|
| "Met1:#14 | FYI | Poll_Delay | The driver has set the default poll delay to the reported |
| ||
| overridden to %d |
|
| value. This setting can be overridden in the configuration |
| ||
|
|
| file.4 |
|
| ||
| Met1:#15 Err. Set MD Length=%d | The driver has determined that the Length parameter is |
| ||||
| too small. The reported length is the driver suggestion. 4 |
| |||||
|
|
|
|
| The parameter called Length must be specified for each |
| |
| Met1:#16 Err. Set MD Length | Map Descriptor. It tells the FieldServer how much Data |
| ||||
| Array space to reserve. Review the Map Descriptor |
| |||||
|
|
|
|
|
| ||
|
|
|
|
| examples in this manual. 4 |
|
|
| MET1:#17 Err. MD too long, | Review the Map Descriptor examples in this manual. 4 |
| ||||
| Max=%u |
|
|
|
|
|
|
| MET1:#18 | Err. | Invalid | Port=%d. | Invalid entry for port.4 |
|
|
| Valid |
|
|
|
| ||
| MET1:#19 |
| Err. | Invalid |
|
|
|
| SubDevice=%d. | Valid | Range=1- | Invalis entry for SubDevice4 |
|
| |
| 64 |
|
|
|
|
|
|
| MET1:#20 Err. Met1_Function not | The parameter “Met1_Function’ must | be specified for |
| |||
| specified |
|
|
| every Map Descriptor. Refer to Section 4.4.2 as well as |
| |
| MET1:#21 |
|
| Err. |
| ||
|
|
| Map Descriptor examples provided in Chapter 4.4 |
| |||
| Met1_Function='%s' | not |
|
|
| ||
| recognized |
|
|
|
|
|
|
Appendix A.1. Driver Operating and Error Statistics
These notes outline any driver specific use of the normal driver operating stats documented in the FieldServer Configuration Manual.
•Timeouts : During normal polling, a timeout can mean that the field device did not respond to the select message, (or the
•Exception Stats: If the driver select a device ,
•Ignored Stats: If the current record is read and there is more data than can be stored than specified by the Length of the Map Descritor then this stat is incremented.
•The driver does not use the normal operating stats to count message and bytes received in response to select / sub select messages.
4Update the configuration file, download the modified configuration file and reset the FieldServer for the changes to take effect
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: 408