Appendix B. Carrier DataLink Device Error Response
The following notes are provided from the protocol specification.
Message | Explanation | Action | |
|
| Check the spelling of the | |
#1 Invalid | The last command sent to the DataLink | command and verify that it | |
Command | device is not recognized. | contains the required | |
|
| parameters. | |
|
| Check the spelling of the table | |
#2 Invalid or Non- | The specified table does not exist in the | name(s). If using a WV or RV | |
command; verify that the table | |||
Existent Table | specified element. | ||
contains the specified | |||
|
| ||
|
| variables. | |
| A Communication error has occurred |
| |
#3 Level II | due to other activity on the CCN | Verify the COMM2 connector | |
Communications | communication bus, a system element | is not disconnected and retype | |
Error | failure, or an incorrect address. The | the command. | |
| command will not be executed. |
| |
|
| Verify that the correct bus and | |
#6 Device Not | The specified system element’s bus and | element number have been | |
the element number were not found in | entered in the | ||
Configured | |||
the | table corresponding to the | ||
| |||
|
| device number. | |
|
| Check the spelling of the | |
#7 Variable Does | The variable does not exist in the | variable name and verify that | |
Not Exist | specified table. | the CCN variable exists in the | |
|
| specified system element. | |
#8 Invalid Data | The data was in an incorrect format. | Verify the format of the data. | |
#9 Access | An attempt was made to read or write to | Check variable. | |
a table or variable type that is not | |||
Restricted | |||
supported by the DataLink device. |
| ||
|
| ||
#10 Limits | The value that was typed is outside the | Verify the limits and adjust the | |
Exceeded | specified variable’s upper or lower limits | force value. | |
#11 Alarms Not | There are no alarms currently in the | Reissue the command at later | |
time or adjust the alarm | |||
Available | alarm buffer. | ||
priority level. | |||
|
| ||
#12 Cannot Force | The CCN system element does not | Choose different variable. | |
allow write access to the specified | |||
Variable | |||
variable. |
| ||
|
| ||
| The | Check the spelling of the point | |
#13 Parameter Not | (variable) name and verify that | ||
used in the RT or WT command does | |||
Found | the point name exists in the | ||
not exist. | |||
| specified system element. | ||
|
| ||
| The command was accepted but not | Retype the command after | |
#14 Level II | understood by the specified system | checking the force priority and | |
element, an attempt was made to write | after verifying that the correct | ||
Communications | |||
to or read a variable with a higher force | bus and element number is | ||
NACK | |||
level, or an attempt was made to write or | entered in the | ||
| |||
| read from a UT203 controller. | table. |