Installation (for qualified installers only) | 2 3 |
Horizontal Terminations using 8” Diameter Vent
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.
20' (max)
15feet
10feet
5feet
0feet
0feet | 5feet | 10feet | 15feet | 20feet | 25'(max) |
Restrictor
Position #7
NOTE:
Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly.
Restrictor
Position #1
(must be placed directly off the top of the fireplace - Part # 925T)
0feet | 5feet | 10feet | 15feet | 20feet | 25'(max) |
20' (max)
15feet
10feet
5feet
0 feet
H2H1
NOTE:
•Horizontal sections require a 1/4" rise every 12" of travel.
•The maximum vertical height is 20'.
•The maximum horizontal length is 25'.
•One horizontal elbow (45° or 90°) is allowed when using 8" vent. The horizontal vent length is calculated by adding the length before and after the elbow (H1 + H2 = horizontal vent length).
Vertical
Elbow
Horizontal
Elbow
Travis Industries | 4040708 | 1 0 0 - 0 1 1 6 0 |