First Virtual Communications PS1010-3A user manual Device operation, Setting output voltage

Models: PS1010-3A

1 10
Download 10 pages 2.42 Kb
Page 5
Image 5
5 Device operation

Voltmeter range

0-35V

5 Device operation

5.1Setting output voltage

Put VM/Vout switch [(10)] to Vout position

Put C/V switch [(8)] to V position

Volt LED indicator will light up [(4)]

[(3)] will display “U” for Volt

Adjust the voltage controller [(5)] to get the required value.

The value will be displayed on [(2)] with one decimal place

Note: Make sure to keep reasonable current limiting value before setting output voltage so that current control (CC) will not take over.

5.2Setting current limit

Press and hold C-SET button [(7)].

Then display[(2)] will show the present current limit in Amperes.

[(3)] will display “A” for Current

Now rotate the current controller knob [(6)] while looking at the display. Stop when the desired value appears.

Note: The output voltage will be automatically be controlled if the external device tries to drag current more than the set limit.

5.3Viewing actual current flow

Power up the DUT with PS1010-3A

IBBI Electronics

5

Page 5
Image 5
First Virtual Communications PS1010-3A user manual Device operation, Setting output voltage, Setting current limit