Fisher & Paykel CG705 Ventilation requirements all countries except UK, Installation instructions

Models: CG705

1 36
Download 36 pages 45.32 Kb
Page 11
Image 11
Ventilation requirements (all countries except UK)

Installation instructions

9

Ventilation requirements (all countries except UK)

Providing adequate ventilation

 

 

 

The installer must refer to the current local regulations.

 

 

 

The room accommodating the gas cooktop must have

 

 

 

adequate natural draught to allow combustion of the gas.

 

450 mm

650 mm

The flow of air must come directly from one or more air vents

made in the outside walls with a free area of at least 100 cm2.

 

 

The vents must be positioned close to the floor, preferably

 

 

 

on the opposite side to the gas burners of your cooker (as

 

 

 

shown in Figs. 1a and 1b). The vents must be designed in

 

 

 

such a way that they cannot be obstructed either from

 

 

 

the inside or the outside.

 

 

 

When it is not possible to provide the necessary vents,

 

 

 

the draught may be supplied from an adjacent room,

 

 

 

ventilated in the required manner, provided it is not a

 

 

 

bedroom or an area at risk. In this event, the kitchen door

 

Extractor

 

must be opened to allow the draught to enter the room.

 

 

 

hood to

mm

 

 

extract steam

Extracting cooking and gas fumes

 

 

650

Important!

 

 

H min

This appliance is not connected to a device extracting the

 

 

 

products of gas combustion. Such a device must be installed

 

 

 

and connected in accordance with the installation rules in force.

 

 

 

Take special care to provide adequate room ventilation as well.

 

 

 

To eliminate cooking and gas fumes, extractor hoods

 

 

 

ducted directly to the outside must be installed. (Fig. 1a).

 

 

 

If this is not possible, an electric fan installed in an

 

Air vent

 

external wall or window may be used; the fan should have

Fig. 2a Ventilation with an extractor hood

a capacity to circulate air at an hourly rate of 3 to 5 times

 

 

 

the total volume of the kitchen (Fig. 1b). The fan can only

 

 

 

be installed if the kitchen has suitable vents to allow air to

 

 

 

enter, as described under ‘Providing adequate ventilation’

 

 

 

above.

 

Electric fan

 

 

 

 

 

 

to extract

 

 

 

steam

 

Air vent

Fig. 2b Ventilation with an electric fan

Page 11
Image 11
Fisher & Paykel CG705 installation instructions Ventilation requirements all countries except UK, Installation instructions