Fisher & Paykel CG705 Gas installation requirements, Installation instructions

Models: CG705

1 36
Download 36 pages 45.32 Kb
Page 15
Image 15
Gas installation requirements

Installation instructions

13

Gas installation requirements

This appliance is adjusted at the factory for use on Natural gas.

To use it on LPG, it will first have to be converted. If the LPG conversion kit is not supplied with the appliance, contact your nearest Authorised Service Centre.

Installation and service regulations (United Kingdom only)

Important!

This appliance must be installed and serviced only by a suitably qualified and registered person, and in accordance with the current editions of the following standards and regulations or other locally applicable regulations:

Gas Safety (Installation and Use) Regulations Building Regulations

British Standards

Regulations for Electrical Installation

Failure to install the appliance correctly could invalidate any manufacturer’s warranty and lead to prosecution under the above-quoted regulation.

Additional gas connection requirements (United Kingdom only)

We recommend connecting the appliance to the gas with a flexible hose made to BS5386. Flexible hoses can be used where the sited ambient temperature of the hose will not exceed

70oC. Any hose used must comply with BS 669, Part 1 and be of the correct construction for the type of gas being used.

Flexible hoses designed for Natural gas MUST NOT be used for supplying LPG (LPG flexible hoses can be identified by either a red band or strip on their outer coating).

Installation and service regulations (all countries)

Important!

This appliance must be installed and serviced only by a suitably qualified, registered installer with technical knowledge of both gas installation and electricity. The installation or service must comply with the current editions of the applicable standards, regulations and codes of practice governing gas and electrical installations.

Failure to install the appliance correctly could invalidate any manufacturer’s warranty.