Converting to a different gas type

Installation instructions

Converting to a different gas type

11

Important!

The conversion procedure must be carried out only by an authorised person.

This appliance is suitable for use with Natural gas or LPG (check the “gas type” sticker attached to the appliance). To convert from one gas type to another, you need to replace the injectors, and then adjust the minimum burner setting.

Replacing the injectors

Remove the trivets and burners from the cooktop.

Using a spanner, remove the injector (Figs. 7 and 8) and replace it with one according to the gas type (see ‘Table for the choice of injectors’).

Fix the warning label supplied with the appliance. This label states that the gas cooktop has been converted for use with LPG/Natural gas.

Where the appliance data plate cannot be easily read with the appliance installed, a second conversion label should also be affixed to an adjacent surface along with the duplicate data plate.

Adjusting the minimum burner setting

Follow the instructions under ‘Adjusting the minimum burner setting’ following.

Important!

If you are converting the cooktop from Natural gas to LPG, remove the gas pressure regulator before connecting the cooktop to the gas supply and replace with the test point adaptor supplied with the conversion kit.

If you are converting the cooktop from LPG to Natural gas, remove the test point adaptor before connecting the cooktop to the gas supply and replace with the gas pressure regulator supplied with the conversion kit.

Note:

- The burners are designed so that regulation of primary air is not required.

Injector

Injector

Fig. 7 Auxiliary, rapid and semi-rapid burners

Fig. 8 Triple-ring wok burner

Page 13
Image 13
Fisher & Paykel CG905 Converting to a different gas type, Injector Injector, Installation instructions