Fisher & Paykel CG905 installation instructions Electrical requirements, Installation instructions

Models: CG905

1 32
Download 32 pages 13.04 Kb
Page 15
Image 15
Electrical requirements

Installation instructions

Important!

13

Installation must be carried out according to the manufacturer's instructions.

Incorrect installation may cause harm and damage to people, animals or property, for which the manufacturer accepts no responsibility.

If the installation requires alterations to the domestic electrical system, call a qualified electrician. The electrician should also check that the socket cable section is suitable for the power drawn by the appliance.

Before carrying out any work on the electrical section of the appliance, it must be disconnected from the electricity supply.

Connection to a good earth wiring system is absolutely essential and mandatory.

The manufacturer accepts no responsibility for any inconvenience caused by failure to comply with this rule.

Electrical requirements

The appliance must be connected to the mains electricity supply checking that the voltage corresponds to the value given in the rating plate and that the electrical cable sections can withstand the load specified on the plate.

The plug must be connected to an earthed socket in compliance with safety standards.

If the appliance is supplied without plug, fit a standard plug which is suitable for the power consumed by the appliance.

The wires in the power supply cable are coloured in accordance with the following code: Green/Yellow = Earth, Blue = Neutral, Brown = Active.

If the colours of the wires in the power cable to the appliance do not correspond with the coloured markings identifying the terminals in the junction terminal, proceed as follows:

1The wire which is coloured green and yellow must be connected to the terminal marked E (Earth) or coloured Green.

2The wire which is coloured blue must be connected to the terminal marked N (Neutral) or coloured Black.

3The wire which is coloured brown must be connected to the terminal marked L (Live) or A

(Active) or coloured Red.

A suitable disconnection switch must be incorporated in the permanent wiring, mounted and positioned to comply with the local wiring rules and regulations. The switch must be of an approved type installed in the fixed wiring and provide a 3 mm air gap contact separation in all poles in accordance with the local wiring rules.

In Australia and New Zealand, a switch of the approved type with a 3 mm air gap must be installed in the active (phase) conductor of the fixed wiring.

The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 50°C above ambient.

Once the appliance has been installed, the switch or socket must always be accessible.

If the power supply cable is damaged, it must be replaced by the manufacturer or its Service Agent or a similarly qualified person in order to avoid a hazard.

Page 15
Image 15
Fisher & Paykel CG905 installation instructions Electrical requirements, Installation instructions