Installation instructions | 7 |
|
Clearances
D |
| A | WARNING! |
| B | This cooktop requires | |
|
|
| adequate supply of cool air |
|
|
| to fully function. |
C |
|
| The base of the cooktop |
|
| must have direct | |
|
|
| |
|
|
| unrestricted ventilation to |
|
| C | the room where the |
| E | cooktop is installed. Follow | |
|
| the requirements below. | |
|
|
| |
|
| 2x | 50mm holes |
|
| to allow adequate | |
|
| cool air |
E
4 mm
E
4 mm
2x 50mm holes to allow adequate
cool airOven with cooling fan
500 x 50 mm
2x 50mm holes to allow adequate cool air
500 x 10 mm
Top of drawer or other obstruction
500x
10mm
Fig. 1 Minimum clearances and ventilation requirements - oven installed below cooktop
Fig. 2 Minimum clearances and ventilation requirements - cupboard or drawer space below
Clearances (mm)
A | minimum clearance from rear edge of cutout to: | |
nearest combustible surface | ||
| ||
B | minimum clearance from glass surface to: | |
rangehood | ||
| ||
C | minimum clearance from side edges of cutout to: | |
nearest combustible surface | ||
| ||
D | minimum clearance from benchtop to: | |
overhead cabinet not directly above the cooktop | ||
|
minimum clearance below top of benchtop to:
Etop of oven* installed below cooktop (see Fig.1) or cabinetry * The oven installed below the cooktop MUST have a cooling fan.
CI604DT | CI754DT | CI905DT |
55 | 55 | 53 |
650 | 650 | 650 |
85 | 78 | 80 |
450 | 450 | 450 |
75 | 75 | 75 |