b2

PRESSURE REGULATOR INSTALLATION

STEP 1

Mount the 1/2” NPT (conical) male connector to the pressure regulator and tighten by using a wrench.

Do not over tighten the connector. Over tightening may crack regulator.

LOCK

Arrow

Fig. 2.2a

14

STEP 2

Assemble the 1/2” NPT connector + pressure regulator group to the extension pipe interposing the gasket supplied. The regulator cover must be ordiented toward the front side of the range.

IMPORTANT: use two spanners to tighten the connection.

Regulator cover

Fig. 2.2b

Page 14
Image 14
Fisher & Paykel OR36SDBGX installation instructions Pressure Regulator Installation Step