Fisher & Paykel OR36SDBGX Conversion to LP/PROPANE GAS, Setting the Pressure Regulator fig

Models: OR36SDBGX

1 52
Download 52 pages 46.08 Kb
Page 19
Image 19

2b

CONVERSION TO LP/PROPANE GAS

Every range is provided with a set of injectors for the various types of gas.

Select the injectors to be replaced according to the “INJECTORS TABLE”.

The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.

SETTING THE PRESSURE REGULATOR (fig. 2.5)

The pressure regulator is accessible through the storage compartment by opening the bottom pivoting panel; the pressure regulator is positioned on the rear left side of the range.

To set the pressure regulator:

1.Unscrew the regulator cover;

2.Unscrew the A component, reverse and screw it according to the LP/PROPANE regulation.

Pressure regulator

LP/PROPANE

REGULATION

NATURAL GAS

REGULATION

REGULATOR

COVER

1

2

A component

Fig. 2.5

19

Page 19
Image 19
Fisher & Paykel OR36SDBGX installation instructions Conversion to LP/PROPANE GAS, Setting the Pressure Regulator fig