2b

SETTING THE BURNER MINIMUM (Valves may vary)

When switching from one type of gas to another, the minimum flow rate must also be correct: the flame should not go out even when passing suddenly from maximum to minimum flame.

To regulate the flame follow the instructions below:

Rapid and triple ring burners

Light the burner

Set the gas valve to LO position

Remove the knob

With a thin screwdriver, turn the regulation screw until adjustment is correct (Fig. 2.7a or 2.7b). On some valves, you need to pass by the hole of the microswitch (Fig. 2.7a) to turn the regulation screw.

Inside crown of DUAL burner

Light the DUAL burner

Set the gas valve to SIM position

Remove the knob

Using a screwdriver turn the screw H until the correct setting is obtained (fig. 2.8).

Outside crowns of DUAL burner

Light the DUAL burner

Set the gas valve to LO position

Remove the knob

Using a screwdriver turn the screw G until the correct setting is obtained (fig. 2.8).

For LP/PROPANE gas, tighten the regulation screws completely.

Regulation screw

Fig. 2.7a

OR

regulation screw

Fig. 2.7b

H

G

Fig. 2.8

21

Page 21
Image 21
Fisher & Paykel OR36SDBGX Setting the Burner Minimum Valves may vary, Rapid and triple ring burners