Fisher & Paykel OR36SDBGX Injectors Table, Operations to be Performed When Substituting Injectors

Models: OR36SDBGX

1 52
Download 52 pages 46.08 Kb
Page 20
Image 20

b2

INJECTORS TABLE

 

 

 

 

LP/PROPANE

NATURAL

GAS

 

BURNERS

NOMINAL POWER

REDUCED POWER

 

11” W.C.P.

 

4” W.C.P.

 

BTU/hr

BTU/hr

 

 

 

 

 

 

 

 

 

Ø injector

 

Ø injector

 

 

 

 

 

 

 

 

 

[1/100 mm]

 

[1/100 mm]

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid (R)

6000

1500

 

72

 

 

118

 

 

 

 

 

 

 

 

 

 

Triple ring (TC)

12000

5000

 

102

 

 

170

 

 

 

 

 

 

 

 

 

 

 

 

Inner crown

2800 for NATURAL GAS (*)

1000 (*)

 

55

 

 

80

 

 

3500 for LP/PROPANE GAS (*)

 

(no. 1 central)

 

 

(no. 1 central)

 

Dual (D)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outer crowns

16000 for NATURAL GAS (#)

6500 for NATURAL GAS (#)

 

72

 

 

130

 

 

 

 

 

 

 

15000 for LP/PROPANE GAS (#)

4500 for LP/PROPANE GAS (#)

 

(no. 2 outer)

 

 

(no. 2 outer)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven burner

21000

2700

135

 

247

 

 

 

 

 

 

 

 

Broil burner

15000

-

115

 

200

 

 

 

 

 

 

 

 

 

 

 

 

(*) Power calculated only with inner crown operating

(#) Power calculated with inner and outer crowns operating

Semi-rapid burner

J

Fig. 2.6a

Triple ring burner

J

Fig. 2.6b

OPERATIONS TO BE

PERFORMED WHEN

SUBSTITUTING THE

INJECTORS

Remove the gratings and the burner covers;

Using a wrench substitute the nozzle injectors “J” (figs. 2.6a - 2.6b - 2.6c) with those most suitable for the kind of gas for which it is to be used.

The burner are conceived in such a way so as not to require the regulation of the primary air.

DUAL burner

J

Injector for inner crown

J

Injectors for outer crowns

Fig. 2.6c

20

Page 20
Image 20
Fisher & Paykel OR36SDBGX installation instructions Injectors Table, Operations to be Performed When Substituting Injectors