b2
INJECTORS TABLE
|
|
|
| LP/PROPANE | NATURAL | GAS | ||||
| BURNERS | NOMINAL POWER | REDUCED POWER |
| 11” W.C.P. |
| 4” W.C.P. | |||
| BTU/hr | BTU/hr |
|
|
|
|
|
|
| |
|
| Ø injector |
| Ø injector | ||||||
|
|
|
| |||||||
|
|
|
|
| [1/100 mm] |
| [1/100 mm] | |||
|
|
|
|
|
|
|
|
|
|
|
6000 | 1500 |
| 72 |
|
| 118 |
| |||
|
|
|
|
|
|
|
|
| ||
Triple ring (TC) | 12000 | 5000 |
| 102 |
|
| 170 |
| ||
|
|
|
|
|
|
|
|
|
| |
| Inner crown | 2800 for NATURAL GAS (*) | 1000 (*) |
| 55 |
|
| 80 |
| |
| 3500 for LP/PROPANE GAS (*) |
| (no. 1 central) |
|
| (no. 1 central) |
| |||
Dual (D) |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| |
Outer crowns | 16000 for NATURAL GAS (#) | 6500 for NATURAL GAS (#) |
| 72 |
|
| 130 |
| ||
|
|
|
|
| ||||||
| 15000 for LP/PROPANE GAS (#) | 4500 for LP/PROPANE GAS (#) |
| (no. 2 outer) |
|
| (no. 2 outer) |
| ||
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |
Oven burner | 21000 | 2700 | 135 |
| 247 |
| ||||
|
|
|
|
|
|
| ||||
Broil burner | 15000 | - | 115 |
| 200 |
| ||||
|
|
|
|
|
|
|
|
|
|
|
(*) Power calculated only with inner crown operating
(#) Power calculated with inner and outer crowns operating
J
Fig. 2.6a
Triple ring burner
J
Fig. 2.6b
OPERATIONS TO BE
PERFORMED WHEN
SUBSTITUTING THE
INJECTORS
✓Remove the gratings and the burner covers;
✓Using a wrench substitute the nozzle injectors “J” (figs. 2.6a - 2.6b - 2.6c) with those most suitable for the kind of gas for which it is to be used.
The burner are conceived in such a way so as not to require the regulation of the primary air.
DUAL burner
J
Injector for inner crown
J
Injectors for outer crowns
Fig. 2.6c
20