Installation instructions
Gas supply
9
The gas connection must be carried out by an authorised person according to the relevant standards.
Before connecting the appliance to the gas main, mount the brass conical adaptor onto the gas inlet pipe, upon which the gasket has been placed (see figures following).
Conical adaptor and gasket are supplied with the appliance (packed with conversion kit for use with Natural gas or LPG gas).
This appliance is suitable for use with Natural Gas or LPG gas. (Check the “gas type” sticker attached to the appliance).
For Natural Gas models the gas supply is connected to the pressure regulator which is supplied with the appliance. Adjust the regulator to obtain a test point pressure of 1 kPa with the two
For LPG gas models the gas supply is connected to the test point adaptor which is supplied with the appliance and ensure that the supply pressure is regulated to 2.75 kPa.
The connection must be made at the rear of appliance (left or right); the pipe is not to cross the cooker.
Close off the unused inlet with the cap and sealing gasket supplied (Fig 7).
IMPORTANT: Use two spanners to tighten or loosen the connecting pipe as shown following.
Gas connection for
LPG GAS
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use suitable seal)
Test point adaptor
Test point
| Gas connection for |
| NATURAL GAS |
| Gas inlet pipe |
| Nipple |
| Gasket |
Test | Brass conical adaptor |
point | (Thread tight: use |
| suitable seal) |
| Gas regulator |
Figure 4 LPG gas connection | Figure 5 Natural gas connection |
|
|
|
|