Fisher & Paykel OR60 Adjusting the minimum burner setting, Table for the choice of the injectors

Models: OR60

1 32
Download 32 pages 4.57 Kb
Page 14
Image 14
Adjusting the minimum burner setting

12

Installation instructions

Adjusting the minimum burner setting

Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to the minimum position. If some ports do not light, increase the minimum gas rate setting.

Check whether the burner remains lit even when the gas tap is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.

The procedure for adjusting the minimum gas rate setting is described below. Turn on the burner

Turn the tap to the MINIMUM position Take off the knob

With a small flat screwdriver turn the screw to the correct regulation.

Note: for LPG gas, the regulation screw is normally tightened up.

Figure 10 Adjusting the minimum burner setting

Table for the choice of the injectors

 

Natural gas

LPG gas

 

 

 

 

 

 

 

Test Point Pressure [kPa]

 

1.0

 

2.75

 

 

 

 

 

 

 

 

Injector

 

Gas

Injector

 

Gas

BURNER

Orifice Dia.

 

Consumption

Orifice Dia.

 

Consumption

 

 

 

 

 

 

 

[mm]

 

[MJ/h]

[mm]

 

[MJ/h]

 

 

 

 

 

 

 

Auxiliary

0.85

 

3.60

0.53

 

3.60

 

 

 

 

 

 

 

Semi-rapid

1.12

 

6.30

0.70

 

6.30

 

 

 

 

 

 

 

Wok

1.65

 

13.30

0.95

 

11.90

 

 

 

 

 

 

 

Page 14
Image 14
Fisher & Paykel OR60 Adjusting the minimum burner setting, Table for the choice of the injectors, Natural gas, LPG gas