Chapter 7

Specifications

Safety and Compliances

Maximum voltage between any terminal and earth ground.

1000 V dc or rms ac

Compliances - DUAL RATINGS

Certifications (Iisted and pending)

Surge Protection

WFuse Protection for mA or μA inputs

Fuse Protection for A input

Markings

Complies with IEC 1010-1 to 1000 V Overvoltage Category III, ollution Degree 2; and IEC 664-1 to 600 V Overvoltage Category

IV, Pollution Degree 2 *

CSA per standard CSA/CAN C22.2 No. 1010.1-92

UL per standard UL 3111 TÜV per standard EN 61010 Part 1-1993

8 kV peak per IEC 1010.1-92

0.44A (44/100 A, 440 mA), 1000 V FAST Fuse 11 A, 1000 V FAST Fuse

P, ),UL, TÜV and #

*OVERVOLTAGE (Installation) Categories refer to the level of Impulse Withstand Voltage protection provided at the specified Pollution Degree.

∙Overvoltage Category III equipment is equipment in fixed installations. Examples include switch gear and polyphase motors.

∙Overvoltage Category IV equipment is equipment for use at the origin of the installation. Examples include electricity meter and primary over-current protection equipment.

7-1

Page 85
Image 85