Specifications | 7 |
Frequency Counter Sensitivity |
Frequency Counter Sensitivity
Approximate VAC Sensitivity
(RMS Sine Wave)1
Input Range
50mV
500mV
3000 mV
5V
50V
500V
1000 V
15 Hz to
100 kHz 2
5mV
20mV
500mV
0.5 V
5V
20V
100V
500 kHz 2
10mV
20mV 2000 mV
2.0V
5.0V
20V
100V
VAC Bandwidth 3
1MHz
1MHz
800kHz
950kHz
1MHz
1MHz
> 400 kHz
Approximate VDC
Trigger Levels 1
5 mV & 65 mV
140 mV & 200 mV
1.4V & 2.0 V
0.5V & 6.5 V
5 V & 65 V
5 V & 65 V
VDC
Bandwidth 3
1MHz
1MHz
90kHz
14kHz
> 400 kHz > 400 kHz > 400 kHz
. 1. Maximum input = 10 x Range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy. 2. Useable at reduced sensitivity to 0.5 Hz and 1000 kHz.
. 3. Typical frequency bandwidth with full scale (or maximum 2 X 107
Burden Voltage (A, mA, µA)
Function | Range | |
mA - ∝ A | 500.00 | ∝ A |
| 5,000 ∝ | A |
| 50.000 mA | |
| 400.00 mA | |
A | 5.0000 | A |
| 10.000 | A |
Burden Voltage (typical)
102 ∝ V / ∝ A
102 ∝ V / ∝ A
1.8mV / mA
1.8mV / mA
0.04V / A
0.04V / A