Specifications

7

Frequency Counter Sensitivity

Frequency Counter Sensitivity

Approximate VAC Sensitivity

(RMS Sine Wave)1

Input Range

50mV

500mV

3000 mV

5V

50V

500V

1000 V

15 Hz to

100 kHz 2

5mV

20mV

500mV

0.5 V

5V

20V

100V

500 kHz 2

10mV

20mV 2000 mV

2.0V

5.0V

20V

100V

VAC Bandwidth 3

1MHz

1MHz

800kHz

950kHz

1MHz

1MHz

> 400 kHz

Approximate VDC

Trigger Levels 1

-5 mV & 5 mV

5 mV & 65 mV

140 mV & 200 mV

1.4V & 2.0 V

0.5V & 6.5 V

5 V & 65 V

5 V & 65 V

VDC

Bandwidth 3

1MHz

1MHz

90kHz

14kHz

> 400 kHz > 400 kHz > 400 kHz

. 1. Maximum input = 10 x Range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy. 2. Useable at reduced sensitivity to 0.5 Hz and 1000 kHz.

. 3. Typical frequency bandwidth with full scale (or maximum 2 X 107 V-Hz product) RMS sine wave.

Burden Voltage (A, mA, µA)

Function

Range

mA - A

500.00

A

 

5,000

A

 

50.000 mA

 

400.00 mA

A

5.0000

A

 

10.000

A

Burden Voltage (typical)

102 V / A

102 V / A

1.8mV / mA

1.8mV / mA

0.04V / A

0.04V / A

7-11

Page 95
Image 95
Fluke 189 user manual Frequency Counter Sensitivity, Burden Voltage A, mA, µA