Fluke 787 user manual Specifications, DC Volts Measurement, Range V dc, Resolution

Models: 787

1 50
Download 50 pages 26.99 Kb
Page 40
Image 40

787

Users Manual

Specifications

All specifications apply from +18°C to +28°C unless stated otherwise.

All specifications assume a 5 minute warmup period.

The standard specification interval is 1 year.

Note

“Counts” means number of increments or decrements of the least significant digit.

DC Volts Measurement

Range (V dc)

4.000

40.00

400.0

1000

Resolution

0.001V

0.01V

0.1V

1V

Accuracy, ±(% of Reading + Counts)

0.1% + 1

0.1% + 1

0.1% + 1

0.1% + 1

Input impedance: 10 MΩ (nominal), < 100 pF

Normal mode rejection ratio: >60 dB at 50 Hz or 60 Hz

Common mode rejection ratio: >120 dB at dc, 50 Hz, or 60 Hz

Overvoltage protection: 1000V