T1 CSU/DSU ASE specifcations
General | Dimensions | 8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm) | |
|
| Plastic case with internal power supply. | |
|
|
| |
| Weight | 2.10 lbs. | |
|
|
| |
| Data Rate | 1.544 Mbps synchronous | |
|
|
| |
| Timing Mode | Derived externally from the T1 network or | |
|
| interface, or internally from the ASE. | |
|
|
| |
Environment | Operating Temperature | 0o to +40oC (+32o to +104o F) | |
|
|
| |
| Storage Temperature | ||
|
|
| |
| Clearance Requirement | Minimum of 3” (7.62 cm) space on sides. | |
|
|
| |
| Operating/Storage Humidity | 10% to 90%, noncondensing | |
|
|
| |
Power Requirements | Input | 100 to 120 VAC | |
|
|
| |
| Frequency | 50/60 Hz | |
|
|
| |
| Input Current Rating | 0.5 amps | |
|
|
| |
T1 Network Interface | Line Rate | 1.544 Mbps ±50 bps synchronous | |
|
|
| |
| Line Format | AMI or B9ZS line coding | |
|
|
| |
| Framing | ESF or D4 framing formats | |
|
|
| |
| ESF FDL | ANSI T1.403, AT&T TR54016, Both, or None | |
|
|
| |
| Input Signal | 0dB to | |
|
|
| |
| Output Signal | 0, | |
|
|
| |
| Pulse Density | AT&T 62411 | |
|
|
| |
| Connector | ||
|
|
| |
| Timing | Loop, | |
|
|
| |
| Channel Selection | 1 to 24 channels in any combination | |
|
|
| |
Network DTE Interface | Configuration | DCE for interfacing with DTE | |
(Data Port) |
|
| |
Data and Clock Leads | |||
| |||
|
|
| |
| Signaling Leads | EIA | |
|
|
| |
| Data Rates | 56 kbps x N or 64 kbps x N (N = 1 through 24) | |
|
|
| |
| HDLC Inversion | Selectable V.35 data inversion | |
|
|
| |
| Transmit Timing Basis | Network | |
|
|
| |
| Receive Timing Basis | SCT, inverted SCT, SCTE | |
|
|
| |
| Receive Line Data Not Valid | RLSD, CTS | |
|
|
| |
| Connector | Female | |
|
|
| |
| Line Rate | 1.544 Mbps ±50 bps | |
|
|
| |
| Line Format | AMI or B8ZS | |
|
|
| |
| Framing | ESF or D4 (SF) | |
|
|
| |
| Input Signal | ||
|
|
| |
| Line Equalization | 0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft | |
|
|
| |
| Connector | ||
|
|
| |
| Channel Selection | 1 to 24 channels in any combination | |
|
|
| |
Serial Port Interface | Specifications | 19200 or 9600 bps baud rate, 8 data bits no parity, | |
|
| 1 stop bit, EIA | |
|
| connector | |
|
|
| |
Ethernet 10/100BaseT | Bite Rate | 10 or 100 Mbps | |
Interface |
|
| |
Connector | |||
| |||
|
|
| |
Modem | Specifications | RJ11 connector, FCC Part 68 and | |
|
| compliance in US and Canada | |
|
|
|
What are ASEs?
ASEs (Analysis Service Elements) are data collection and network performance monitor- ing hardware devices placed on a wide area network (WAN) or Local Area Network (LAN) as part of the Visual UpTime Select system, which offers
Hardware Warranties
Enhanced Gold, Bronze, and International Gold ASE hardware warranty service programs are available to help you maximize your investment in Visual UpTime Select. For more detailed warranty information, visit: www.flukenetworks.com/visualcustomercare
Ordering Information
For more details, please contact your Visual UpTime Select authorized reseller or Fluke Networks Sales at (800)
N E T W O R K S U P E R V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA
Fluke Networks operates in more than 50 countries worldwide. To find your local office contact details, go to www.flukenetworks.com/contact.
©2006 Fluke Corporation. All rights reserved. Printed in U.S.A. 2/2006 2643363