Electromagnetic Compatibility in RF field of 3 V/m on all functions except MΩ
Relative Humidity except 32 MΩ Range:
32 MΩ Range only:
Altitude
Battery Type
Battery Life
Continuity Beeper
Shock, Vibration
Size (H x W x L)
Weight
Safety
EMC Regulations
Certifications/Listings
Total accuracy = Specified accuracy plus +2.0% of range for all functions except:
320.0mV range: total accuracy = specified accuracy + 1.0% of range
320.0Ω range: total accuracy = specified accuracy + 8% of range
0% to 90% (0°C to 35°C)
0% to 70% (35°C to 50°C)
0% to 80% (0°C to 35°C)
0% to 70% (35°C to 50°C)
Operating: 2000 meters
Storage: 12,000 meters
9 V, NEDA 1604 or 6F22 or 006P, or NEDA 1604A or 6LR61
2000 hrs typical with alkaline
1600 hrs typical with carbon zinc
4096 Hz
per
2.8cm x 7.5 cm x 16.6 cm (1.12 in x 2.95 in x 6.55 in)
340 g (12.0 oz)
600 V CAT II per ANSI/ISA S82.01- 1994, EN
EN