Franke Consumer Products FTU 3807 W manual Hood support mounting

Models: FTU 3807 W

1 52
Download 52 pages 11.46 Kb
Page 19
Image 19
Hood support mounting

Hood support mounting

• Lean the hood support 3 against the wall making sure that holes in the hood support correspond to those in the wall.

• Block the hood support to the wall using 4 12a (5 x 70) screws 12a supplied with the hood.

Before fastening the screws definitively make sure that the support is well-levelled. Only after this operation proceed with the definitive tightening of the screws.

Air outlet connection in the ducting version

When installing the hood in ducting version, basing on the in- staller’s choice, a rigid or a flexible pipe with a ø 150 o 120 mm is used in order to connect the hood to the air outlet piping. The pipe connection can be made on the upper part or on the back side of the hood.

AIR OUTLET ON THE BACK SIDE OF THE HOOD

When drilling the air outlet hole in the wall proceed in accor- dance with the scheme in the paragraph concerning the wall drilling.

In case the connection is made with a ø 120 mm pipe insert the reduction flange 9 on the hood body outlet.

Fix the pipe with an adequate quantity of pipe clamps. This material is not supplied together with the hood.

Remove the charcoal filter if present.

AIR OUTLET ON THE UPPER PART OF THE HOOD

In case the connection of the hood to the air outlet piping is made with a ø 150 mm pipe then use a rigid or a flexible pipe.

In case the connection is made with a ø 120 mm pipe insert the reduction flange 9 on the hood body outlet.

Fix the air outlet reduction 8c to the air outlet hole of the hood support with the screws supplied together with the hood.

Connect the hood to the piping with a rigid or a flexible pipe.

Fix the pipe with an adequate quantity of pipe clamps. This material is not supplied together with the hood.

Remove the charcoal filter if present.

3

8c

ø 120

9

ø 150

EN

 

1

 

19

Page 19
Image 19
Franke Consumer Products FTU 3807 W manual Hood support mounting, Air outlet connection in the ducting version