Friedrich 920-087-09 operation manual Wall Sleeve Attachment, Dimensions

Models: 920-087-09

1 36
Download 36 pages 62.92 Kb
Page 10
Image 10
Wall Sleeve Attachment
EXPANSION ANCHOR BOLT

Figure 8

Wall Sleeve Attachment

WALL

SLEEVE

ALTERNATE FASTENING METHODS (Field Supplied)

WOOD SCREW

TOGGLE BOLT

NOTE: The Wall Sleeve must be horizontally level (side-to-side) and pitched 1/4 bubble to the outside when installed in an opening.

The mounting hole location should be approximately 2-4” from the top and bottom of the sleeve.

MOUNTING

HOLES

PLASTIC ANCHORS

SCREWS

FRP007

 

Figure 9

Dimensions

DimensionsAManual background

Manual background ¼" MIN.

C

 

A

 

B

C

Dimension*

Allow

Allow

Allow

 

for wall

for floor

for proper

 

finishing

finishing

drainage

 

(Minimum)

Min.

Max.

(Front-to-Back)

 

 

 

 

 

No Accessories

¼"

¼"

---

---

 

 

 

 

 

With Subbase

1-¾"

3-½"

5"

---

Manual background 13-¾"Manual background

B

Manual background WALL

With Lateral Duct

¾"

¼"

---

---

 

 

 

 

 

Wall Sleeve Tilt

---

---

---

¼"

 

 

 

 

 

*If more than one accessory is to be used, use the maximum dimension. If the wall thickness is more than 13-¾" - (A+ ¼"), a sleeve extension must be used.

FRP009

8

Page 10
Image 10
Friedrich 920-087-09 operation manual Wall Sleeve Attachment, Dimensions