Internal Drain

PXDR10 Drain Kit Installation Instructions (optional for new construction)

NOTE: Determine whether drain will be located within the wall, on the indoor side, or will drain to the exterior of the building. Follow appropriate instructions below depending on your particular type of installation.

Internal Drain

NOTE: If installing an internal drain, you MUST install a drain kit on the wall sleeve before the wall sleeve is installed.

1.Refer to Figure 11 and locate the drain within the “Preferred” area of best drainage. Maintain at least a ½” clearance from the embossed area.

2.Using the mounting plate with the ½” hole as a template, mark and drill two, 3/16” mounting holes and a ½” drain hole in the sleeve bottom.

3.Remove the backing from the gasket and mount it on the flat side of the mounting plate. (See Figure 12, Page 11). Insert the drain tube through the hole in the gasket and mounting plate so the tube flange will be against the wall sleeve.

4.Position the assembly beneath the drilled holes and secure it with

#10-24 x ½" machine screws and lock nuts provided. Seal the tops of the screws with silicone caulking.

5.Use ½" I.D. copper tube, PVC pipe, or vinyl hose (obtained locally) to connect the internal drain tube to the drain system in the building.

6.Referring to Figure 12, Detail A, Page 11, locate and assemble the

(2) two cover plates and gaskets over the drain holes at the rear of the wall sleeve. Attach them with the #10 sheet metal screws provided. Make certain that the four overflow slots at the rear of the wall sleeve are not blocked (See drawing of the back of the sleeve Figure 12, Page 11).

7.If a deep wall extension (PDXWSEXT) is used, after installing the field supplied flashing, caulk as required. Be sure to caulk around the flashing and the wall sleeve where the hole was drilled for the drain tube.

Figure 11

Drain Kit Location and Installation

OPTIONAL AREA

PREFERRED AREA-

NO FOAM INSULATION

IF THE DRAIN MUST BE

 

LOCATED IN THE OPTIONAL

 

AREA, THE FOAM INSULATION

 

MUST BE CUT AWAY AND

3"

REMOVED TO ALLOW ACCESS

TO THE DRAIN.

 

SCREW

WALL SLEEVE

Drain Kit Location and Installation GASKET

MOUNTING

PLATE

DRAIN TUBE

NUT

SIDE VIEW

 

 

FRONT VIEW

 

 

FRP011

 

 

 

 

 

 

 

 

PXDR10

 

QUANTITY

DESCRIPTION

 

2

COVER PLATES

 

1

MOUNTING PLATE

 

1

DRAIN TUBE

 

3

MOUNTING PLATE GASKET

 

4

#10 X ½” SHEET METAL SCREWS

 

2

#10-24 X ½ ” MACH. SCREWS

 

2

#10-24 X ½" LOCKNUTS

10