A. BEFORE INSTALLATION
1.Insert the guide panels into the guides of the air conditioner. Fasten the curtains to the unit with screws (TYPE A) as shown Fig. 6.
2.Cut the
Remove the backing from the seal strip and attach the seal strip to the underside of the bottom window. (Fig. 7)
B. BEGIN INSTALLATION
1. LOCATING UNIT IN WINDOW
Open the window and mark center line on the center of the inner sill, as shown in Fig. 8.
2.ATTACH L BRACKET
a.Install the L brackets behind the inner window sill, with the short side of bracket as shown. Use the 2 screws (TYPE A) provided.
b.The bracket helps to hold unit securely in place. Be sure to place bracket edge flush against back of inner sill. See Fig. 9.
3.INSTALL THE AIR CONDITIONER IN THE WINDOW
a.Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the L bracket. See Fig. 9.
CAUTION
During the following step, hold unit firmly until window sash is lowered to top channel behind
TYPE A
Fig. 6 | TYPE A |
|
SEAL STRIP (TYPE D)
Fig. 7
CENTER LINE
INNER SILL
ROOM SIDE
Fig. 8
INNER SILL
OUTER SILL | TYPE A INSIDE |
| CENTER LINE |
| 8" |
SHORT SIDE | 8" |
OUTSIDE |
|
LBRACKET
side panel frames. Personal injury or property damage may result if unit falls from window.
IMPORTANT :
When the air conditioner drops into the L bracket, the air conditioner will be centered in window opening as shown in Fig. 10.
Fig. 9
Fig. 10
CENTER LINE
10