STEP 3 Slide the cabinet into the hole far enough to allow the
STEP 4 Drill three (3) 5/32" diameter pilot holes through holes in
NOTICE
Instructions for mounting sleeve with slope must be observed to prevent entry of water into room.
Potential property damage can occur if instructions are not followed.
FIGURE O | TYPICAL INSTALLATION | |
TRIM MOULDING | CAULK ALL SIDES AIR TIGHT | |
| ||
| 3/8" (10 MM) SLOPE DOWN | |
| NOTE: SUPPORT BRACKETS MAY BE OMITTED FROM | |
SCREW #12A X 2" LONG | ||
SECURED AS FOLLOWS. DRILL 2 HOLES IN EACH SIDE | ||
USE 3 | ||
AND INSTALL 4 FASTENERS (2 EACH SIDE). | ||
| ||
| USE #12A X 2" (51 MM) SCREWS, TOGGLE BOLTS OR | |
| EXPANSION ANCHOR BOLTS AS SHOWN IN STEP 5. |
SILL PLATE GUIDE CHANNEL |
| |
| SUPPORT BRACKETS (ITEM 1) (SEE NOTE ABOVE) | |
INSIDE WALL SURFACE | SCREW #12 X 2" LONG, USE ONE IN EACH | |
BRACKET. DRILL 5/23 (4 MM) DIA. PILOT HOLES. | ||
|
NOTE: ALTERNATE FASTENERS WHICH MAY BE USED FOR SECURING THE SILL PLATE IN THE WALL, AND THE SUPPORT BRACKETS TO THE OUTSIDE WALL ARE NOT FURNISHED, BUT ARE AVAILABLE AT A LOCAL HARDWARE STORE.
MOLLY OR TOGGLE BOLT | EXPANSION ANCHOR BOLT |
STEP 5 Drill two (2) 5/32" (4 mm) dia. pilot holes in each side at the locations shown (Figure O) and install four (4) #12 x 2" screws (Item #4). If the hole construction in Step 2 provides a sturdy mount with solid vertical studs, no support brackets are required. The installation must support the weight of the unit plus an additional weight of 400 pounds (185 kg) on the rear of the cabinet. The support brackets may be used for
STEP 6 If desired, trim around the cabinet on the room side with a suitable frame molding furnished by the installer (See Figure O).
15