How to Install the Unit

12

How to Install the Unit

1.To prevent vibration and excess noise, make sure the unit is installed securely and firmly

2.Install the unit where the sunlight does not shine directly on the unit.

3.The outside of the cabinet must extend outward for at least 12" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet, as it will prevent heat radiation of the condenser.

Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

Cooled air

30"~60"

Fence

Awning

Heat radiation

About 1/2"

Over 20"

CAUTION: All side louvers of the cabinet must remain exposed and unobstructed to the outside of the structure.

4.Install the unit with a rear, downward slope, so the back is slightly lower than the front (about 1/4" buble on a level). This will force condensation to flow to the outside.

5.Install the unit with the bottom about 30"~60" above the floor level.

 Window Requirements Window Requirements

NOTE: All supporting parts should be secured to firm wood, masonry, or metal.

This unit is designed for installation in standard double hung windows with actual opening widths from 22" to 36".

The top and bottom window sash must open sufficiently to allow a clear vertical opening of 15" from the bottom of the upper sash to the window stool.

22" to 36"

 

 

15" min

Stool

(With frame curtain)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interior wall

20 1/12" min.

(Without frame curtain)

Offset

1/2" to 11/4"

Sill

Exterior

10