Frigidaire 316259343 dimensions Provide an adequate gas supply, Seal wall openings, b, c

Models: 316259343

1 16
Download 16 pages 56.53 Kb
Page 4
Image 4
Fig. 4a

30"GASRANGEINSTALLATIONINSTRUCTIONS

(For Models with Sealed Top Burners)

C. Level and Position Range - Level range by adjusting the

(4) leveling legs with a wrench. Note: A minimum clearance

of 1/8" is required between the bottom of the range and the

leveling leg to allow room for the bracket. Use a spirit level

to check your adjustments. Slide range back into position.

4.Connect the range to the gas supply.

NOTE: To prevent leaks use pipe joint sealant on all male (outside) pipe threads.

Visually check that rear leveling leg is inserted into and

fully secured by the Anti-Tip Bracket by removing lower

panel or storage drawer. For models with a warmer drawer

or broiler compartment, grasp the top rear edge of the

range and carefully attempt to tilt it forward.

*Please note: Models without self-cleaning feature may have an additional 4 to

7inches clearance from the floor.

*15"

 

C

 

L

 

Centerline

 

of range

 

11-1/2"

 

23"

7"

2"

 

Recommended area for 120V outlet on rear of wall and area for thru the wall connection of pipe stub and shut-off valve is shaded area.

 

10-

 

1/2"

 

Recommended area for thru

Fig. 4a

the floor connection of

pipe stub and shut-off valve.

Wall

Edge

2. Provide an adequate gas supply.

 

This unit is pre-set to operate on 4" natural gas manifold

 

pressure. A convertible pressure regulator is connected to the

 

manifold and MUST be connected in series with the gas supply

 

line. If the LP/Propane conversion kit has been used, follow

 

instructions provided with the kit for converting the pressure

 

regulator to LP/Propane use. The LP kit can be found on the

 

back side of the range (some models).

 

Care must be taken during installation of range not to obstruct

 

the flow of combustion and ventilation air.

Fig. 4b

 

For proper operation, the maximum inlet pressure to the

 

regulator should be no more than 14 inches of water column

 

pressure. The inlet pressure to the regulator must be at least

 

1 inch greater than regulator manifold pressure. Examples: If

 

regulator is set for natural gas 4 inch manifold pressure, inlet

 

pressure must be at least 5 inches; if regulator has been

 

converted for LP/Propane gas 10 inch manifold pressure, inlet

 

pressure must be at least 11 inches.

 

Leak testing of the appliance shall be conducted according to

 

the instructions in step 4g.

 

The gas supply line should be 1/2" or 3/4" I.D.

 

3. Seal wall openings.

 

Seal any openings in the wall behind the range and in the floor

 

under the range after gas supply line is installed.

 

 

Fig. 4c

4

Page 4
Image 4
Frigidaire 316259343 Provide an adequate gas supply, Seal wall openings, b, c, 30GASRANGEINSTALLATIONINSTRUCTIONS