ENG
Gas installation
01.This range was designed for use with LP gas.
02. Always use a pressure |
regulator exclusive for your gas |
range. The lack of pressure |
regulator might cause excess |
of pressure and leak of gas. |
Always check for the validity of |
the pressure regulator. Hose |
and regulator should be |
replaced every 5 years. |
Technical specification of the |
Pressure regulator
Attention
If you have any doubt or need to buy any accessory for the installation, please contact our authorize service.
ENG
Plastic Hose
pressure regulator: |
• Pressure: 200 mm C. A. |
• Max. consumption: 2 kg/h |
03.Always use a PVC hose to work from
•does not have joins.
•does not go on the back of the gas range neither close to the hot air exits.
•its less than 125cm long.
04.If possible, install the gas cylinder outside the kitchen, in a place protected and with air flow.
05.Use a 1/2"metallic hose to connect to the gas range using a L coupling connector.
06.Only use a plastic hose when this one does not go on the back of the gas range.
Metalic flexible tube
L coupling
connector
Hose installation
01. Place the metal clamp on the hose end.
02. Connect the hose to the oven connector and tight the clamp.
03.Place the other clamp on the opposite hose end and connect it to the pressure regulator. Tight the clamp.
04. Bolt the pressure regulator to the gas cylinder carefully.
05.After the installation, check if there is any gas leak, using soap or liquid detergent foam
Connector
41 | 42 |