4-9
4.9 Fryer Setup Mode Programming The computer, upon initial power up, when changing out a computer or accessed from Level 1,
enters setup mode. These parameters need to be set to allow the auto filtration, logs and other
functions to operate correctly. The setup sets the time, date, date format, language, fryer type, vat
type, oil system type and the temperature scale from F° to C°. These settings should only be changed
by a technician.
On initial power up the computer displays OFF.
1. Press either soft power button or with the computer OFF, enter Level 1 programming mode by
pressing the TEMP and INFO buttons simultaneously until LEVEL 1 is displayed.
2. The computer displays FRYER Setup if initially powering up the computer and/or
ENTER CODE if programming through Level 1.
3. Enter 1234 (see Figure 4).
If initially powering up the computer skip to step 6,
otherwise if programming through Level 1 continue to the
next step.
1
2
3
4
(1234)
Figure 4
The computer displays level 1 program for three seconds and sounds an alert.
The computer then displays Product selection.
4. Press the u button to scroll to FRYER SETUP. Press the (1 yes) button (see Figure 7).
Computer displays ENTER CODE.
5. Enter 1234 (see Figure 5).
1
2
3
4
(1234)
Figure 5
Computer displays time format.
6. Use the 3and 4 buttons (see Figure 6) to toggle between
24hr and 12hr.
7. With the desired selection displayed, press the (1
yes) button (see Figure 7).
Figure 6 Figure 7
The computer displays ENTER TIME on the left and hh:MM on the right.
Example: 7:30 AM is entered 0730 if using the 12 hour format. 2:30 is entered 1430 if using 24 hour
format.